B&K's General Purpose Power Supplies

 

Model 1735 / Model 1710

* Built-in voltmeter * Reverse polarity protection
* Parallel or series connection * Regulated outputs - constant volt or current * Low ripple characteristics * Overload protection; fully adjustable current limiting

Common Characteristics

1735

 

1710

Output Voltage

0-30 VDC

 

0-30 VDC

Constant Voltage Operation

Voltage Regulation Line(110-130V)

0.02%+2mV

 

0.03%+2mV

Load (No Load to Full Load)

0.02%+3mV

 

0.04%+3mV

Recovery Time

200ns

 

200ns

Ripple Voltage

P-P 2mV rms

 

3mV rms

Constant Current Operation

Adjustable Current Limits

5% to 100%

 

5% to 100%

 

0.15A to 3A

 

0.05A to 1A

Current Regulation Line (110-130V)

5mA typical, 9mA max.

 

6mA typical

Load Regulation

5mA typical, 9mA max.

 

5mA typical, 12mA max.

Current Ripple

3mA typical

 

2mA typical

Protection

 Reverse Polarity Protection Current Limiting

 

 Reverse Polarity Protection Current Limiting

Metering Type

3.5 Digit LED

 

Analog

Functions

Volts, Amps, External Volts

 

Volts, Amps, External Volts

Voltmeter Range

0 to 199.9V

 

0 to 32V

Voltmeter Accuracy

.5%+2 digits

 

+-2.5%

Ammeter Range

0 - 19.99A Low: 0 - 1.6A

 

High:0 - 1.04A

Ammeter Accuracy

0.5%+2 digits

 

+-2.5%

Power Requirements

 110/120/220/240 VAC +-10%, 50/60 Hz

 

 110/120/220/240 VAC +-10%, 50/60 Hz

Power Consumption Approx. or Less at Full

175W

 

60W

Dimensions (HxWxD)

 6-3/4 x 4-11/16 x 12" (172 x 119 x 305mm)

 

 6-3/4 x 4-11/16 x 12" (172 x 119 x 305mm)

Weight

11-1/4 lbs.

 

8 lbs.

Our Part No.

3T6-535

 

3T6-520

Price

$380.00

 

$229.00

Accessories Included: Hook-up leads, spare fuse, parts list, instruction manual, and schematic diagram.

 

Digital Triple Output Power Supply

Model 1660

* Adjustable current limit controls - 30 V sections
* Two 0-30 VDC, 2A sections capable of independent or tracking operation
* Two 3.5 digit LED displays
* Switchable series/parallel operation - 30 V sections
* One 4-6.5 VDC, 5A section
* Constant current and constant voltage indicators - 30 V sections
Part No. 3T6-560

$649.00

SPECIFICATIONS

Output Voltage Range: 0V to 30V (Master & Slave). Output Current Limit Range: 0A to 2A (Master & Slave). Load Regulation: (Constant Voltage) 0.01% + 3mV (Master & Slave). Line Regulation 108-132V: (c.v.) 0.01% + 3mV (Master & Slave). Ripple: RMS (c.v.) 1mV (Master & Slave). Recovery Time: (c.v.) 100uS. Load Reg. (Constant Current) 0.2% + 3mA (Master & Slave). Line Regulation 108-132V: (c.c.) 0.2% + 3mA (Master & Slave). Ripple Current (at 108V): (c.c.) 3mA RMS (Master & Slave). Master/Slave Tracking: (Series) 0.2% + 10mV. Volts Panel meter Accuracy: 0.5%+2 (Master & Slave), 0.5%+2 (4-6.5V). Current Panel Meter Accuracy: 0.5%+2 (Master & Slave), 0.5%+2 (4-6.5V. Output Voltage Adj. Range: (4-6.5V) from 4V to 6.5V. Load Regulation: (Constant Voltage) 10mV (4-6.5V), (0-5A load). Line Regulation 108-132V: (c.v.) 10mV (4-6.5V). Ripple & Noise: 2mV RMS (4-6.5V). Over Voltage Protection Threshold: 6.8V to 7.3V. Power: 110, 120, 220, 240 VAC, 50/60Hz. Power Consumption: Fully loaded approx. 320W. Protection: Reverse polarity and current limiting. Dimensions (HxWxD): 12.4 x 15 x 6.5" (315 x 381 x 165mm). Weight: 22 lbs. (10kg). Accessories Supplied: Two 5A, 250V fuses (spares), three sets of leads, manual, schematic and parts list.


Isolated-Variable AC Power Supplies

Model 1655

* Expanded leakage scale 8 Power line leakeage tester
* Displays volts, amps, VA, leakage
* Circuit breaker overload protection
* Variable-isolated output-0-150 VAC
* 3 Amp continuous, 4 amp intermittent output
* Built-in solid state soldering iron temperature control
Part No. 3T6-555

$529.00

SPECIFICATIONS

Voltage Adjustment Range: 0-150VAC, with input at 120VAC. Output Isolation: Leakage less than 0.1mA. Current Ranges: 0-2A, 0-4A. Max. Current (Isolated): 3A continuous, 4A intermittent (0-130V). Peak Current (Inrush): 30A max. (Inrush limited to one cycle at 30A.) Voltage/Current Sensing: Sine wave average, calibrated in RMS. Volt-Amp Ranges: 0-240VA, 0-480VA (voltage set at 120V). Leakage Range: 0 to 5,000 microamps (expanded in 100-500 microamp portion, compressed to 5mA full scale). Meter: 4-1/2" multicolor scales, over range protected. Meter Accuracy: 5% full scale (volts and current); 5% at 500 microamps (leakage). Solder Iron Temp. Control: 70%-90% of power line (100W max.). Power: 120VAC, 60Hz, 600VA at max. output. Dimensions (HxWxD): 12 x 6 x 11" (30.5 x 15.2 x 28.0cm). Weight: 22 lbs. (10kg).

 

 

 